Figure 5-7 - Oil Change Interval - Gardner Denver EBM99M 60 Operating And Service Manual

Electra-saver, electra-saver ii stationary base-mounted compressor
Table of Contents

Advertisement

Up to 180° F (82° C)
180° F to 190° F (82° C to 88° C)
190° F to 200° F (88° C to 93° C)
200° F+ (93° C)
DRAINING AND CLEANING OIL SYSTEM
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
Always drain the complete system. Draining when the oil is hot will help to prevent varnish deposits and
carry away impurities.
To drain the system, use one of the following methods:
1.
If the unit is not elevated high enough to use the oil reservoir drain line to drain oil, a small
hand, electric or air operated pump should be used to drain reservoir through the oil filler
opening or from the drain valve.
2.
If the unit is elevated so that the oil reservoir drain can be used, empty the oil reservoir through
the drain valve to a suitable container or sump.
3.
If the drained oil and/or the oil filter element are contaminated with dirt, flush the entire system:
reservoir, oil cooler, mixing valve and lines. Inspect the oil separator elements for dirt
accumulation; replace if necessary. If a varnish deposit exists, contact the factory for
recommendations for removal of the deposit and prevention of varnish.
Discharge
Temperature
Figure 5-7 – OIL CHANGE INTERVAL
C C
A A
U U
C
A
U
13-21-603
AEON 4000
AEON 9000 SP
Change Interval
Change Interval
4000 hrs.
3000 hrs.
2000 hrs.
1000 hrs.
T T
I I
O O
N N
T
I
O
N
Page 74
8000 hrs.
6000 hrs.
4000 hrs.
2000 hrs.