Figure 1-2 - Starter Box; Figure 1-3 - Control Box - Gardner Denver EBM99M 60 Operating And Service Manual

Electra-saver, electra-saver ii stationary base-mounted compressor
Table of Contents

Advertisement

LUBRICATION, COOLING AND SEALING - Oil is forced by air pressure from the oil reservoir through
the oil cooler, thermostatic mixing valve, and oil filter and discharges into the compressor main oil gallery.
A portion of the oil is directed through internal passages to the bearings, gears and shaft oil seal. The
balance of the oil is injected directly into the compression chamber to remove heat of compression, seal
internal clearances and lubricate the rotors.
TURN VALVE (ELECTRA-SAVER ONLY) - The turn valve is a rotary helical valve located on the
discharge side of the cylinder toward the inlet end. The valve opens and closes ports in the cylinder
which communicates with the inlet passage. This varies the compressor rotor volume to match the
demand for air, thus reducing the part-load power requirement.
Figure 1-2
– STARTER BOX
Figure 1-3 – CONTROL BOX
13-21-603
Page 10
217ECM797-A
(Ref. Drawing)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eam99eEap99lEbp99l

Table of Contents