Gardner Denver EBM99M 60 Operating And Service Manual page 37

Electra-saver, electra-saver ii stationary base-mounted compressor
Table of Contents

Advertisement

COMPRESSOR CAPACITY CONTROL - TURN VALVE UNITS ONLY
The capacity of the compressor is controlled by the action of the turn valve and the compressor inlet
valve.
The turn valve controls compressor delivery to match demands of 40% to 100% of the compressor's
maximum capacity. The inlet valve throttles to control compressor delivery to match demands of 0% to
40% of the compressors maximum capacity.
Example with normal setting of 100 PSIG:
Compressor Delivery
Capacity
Full
70%
40%
30%
20%
0%
Inlet Valve
Open
Open
Open
Closing
Closing
Closed
13-21-603
Turn Valve
Closed
50% Open
Full Open
Full Open
Full Open
Full Open
Page 36
Discharge Manifold
Pressure
100
100
100
103
103
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eam99eEap99lEbp99l

Table of Contents