Figure 2-5 - Heat Exchanger (Oil Cooler) Approximate Water Flow; Figure 2-6 - Aftercooler Approximate Water Flow - Gardner Denver AUTO SENTRY EAU99G Operating And Service Manual

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

KW
Model
150
EAU99H
186
EAU99H
224
EAU99H
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
Figure 2-5 – HEAT EXCHANGER (OIL COOLER) APPROXIMATE WATER FLOW
HP
Model
200
EAU99G & M
250
EAU99G & M
300
EAU99G & M
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
HP
Model
150 KW
EAU99H
186 KW
EAU99H
224 KW
EAU99H
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
Figure 2-6 – AFTERCOOLER APPROXIMATE WATER FLOW
HEAT EXCHANGER (INTERNATIONAL)
Water Temperature to Heat
Exchanger
(ls)
16° C
21° C
27° C
1.2
1.5
2.0
1.5
1.9
2.5
1.8
2.3
3.1
AFTERCOOLER (DOMESTIC)
Water Temperature to Heat
Exchanger
(gpm)
60° F
70° F
80° F
3.0
3.7
5.0
3.8
4.8
6.4
4.6
5.8
7.7
AFTERCOOLER (INTERNATIONAL)
Water Temperature to Heat
Exchanger
(ls)
16° C
21° C
27° C
0.2
0.2
0.3
0.2
0.3
0.4
0.3
0.4
0.5
13-10-614
Maximum
Water Flow
(ls) *
32° C
3.0
7.0
3.8
7.0
4.6
7.0
Maximum
Water Flow
(gpm) *
90° F
7.5
110
9.5
110
11.6
110
Maximum
Water Flow
(ls) *
32° C
0.5
7.0
0.6
7.0
0.7
7.0
Page 15
Approximate Water
Pressure Drop @ 32° C
Water Temperature Bar
Less than .15 bar for any
flow rate shown in the
table
Approximate Water
Pressure Drop @ 90° F
Water Temperature
(psi)
Less than 1 psi for any flow
rate shown in the table
Approximate Water
Pressure Drop @ 32° C
Water Temperature BAR
Less than .1 bar for any
flow rate shown in the table

Hide quick links: