Danfoss 140F1143 Installation Manual page 17

Intelligent electronic timer thermostat or timer switch with wi-fi connectivity and app control
Table of Contents

Advertisement

DEVIreg™ Smart
Error
type
Floor
Sensor
discon-
nected
Floor
Sensor
short-
circuited
Thermo-
stat over-
heated
Unrecov-
erable
error
Installation Guide
Nr�
Description
E1
Connection
to sensor is
lost
E2
Sensor short-
circuited
E3
Thermostat
is overheat-
ed, heating is
turned off
E4
Room
temperature
sensor value
too high or
too low
Solution
Need restart
Contact
The thermostat
service
requires a restart
to operate again.
Contact
The thermostat
service
requires a restart
to operate again.
Wait until
The thermostat
thermo-
requires no
stat cools
restart, but will
down
start heating
when the
temperature is
lowered
Contact
The thermostat
service
requires a restart
to operate again.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Devireg smart140f1142140f1141140f1140

Table of Contents