Overheat protector of the device can also go
!
off at temperatures below -5˚C / 23˚F (stor-
age, transport, environment). Before instal-
lation take the device to the warm environment.
The overheat protector can be reset when the tem-
perature of the device is approx 18˚C / 64˚F. The
overheat protector must be reset before using the
device.
Receptacles OR PLUGS are not allowed in a Sauna
room. If a speaker is installed in a Sauna room, it
should not be installed higher than 3' (900 mm)
from floor, away from the Sauna heater (consult
manufacturer for ratings).
ROOM LIGHT should be a vapor proof, wall-
mounted type, with rough-in box mounted flush
with inside paneling. It should mount 6'6" from
floor, not directly over Sauna heater, and not over
upper benches; light bulb should not exceed 75
watts. NOTE! Heat may cause accelerated wear on
lighting, for longest lasting results, place lights low
in room away from heater. Under benches is an
ideal location.
HEATER FENCE is necessary for safety and should
be constructed of 1" x 2" (25 x 50 mm) or 2" x 2"
(25 x 50 mm) softwood to match Sauna interior.
See figures 2–4 for clearances from Sauna heater.
Fence should attach to wall and should not be
placed higher than top of heater below rock line.
ROOM CONSTRUCTION –
GENERAL INFORMATION
A. FRAMING
2" x 4" (50 x 100 mm) any suitable wood
material, 16" (406 mm) o.c.
B. CEILING HEIGHT
no higher than 7'0" (2100 mm).
C. INSULATION
Fiberglass or rock wool insulation with a
minimum R11 insulating factor in all walls and
ceiling. Paper-backed aluminum vapor barrier
installed over insulation on all walls and ceiling
with aluminum side facing into the sauna room.
D. DRYWALL
See local codes. Is not required in most
residences. See local codes commercial. If
drywall is used, apply 1" x 2" (25 x 50 mm)
nailers so that wall and ceiling boards can be
attached to solid wood.
E. PANELING
Use kiln-dried clear tongue & groove softwood,
such as Spruce, Pine, Aspen, Alder, Cedar, or
other suitable softwood material (with moisture
content not exceeding 11%).
F. BENCHES
Use matching wood or other suitable wood
as described in section E. Minimize knots on
seating area as knots can become very hot and
may be uncomfortable for bathers. Fasten from
bottom to prevent burning.
G. HEATER GUARDRAIL
Use matching softwood.
H. DOOR
Must open out and should not have a lock.
I. FLOORING
concrete, ceramic tile, or heavyduty Vinyl.
J. VENTILATION
should be provided by intake vent close to
heater, 2" (50 mm) from floor, and out vent
on opposite wall (if possible) 10" (250 mm)
to 12" (300 mm) from floor. Vents should be
adjustable and should allow air to change 5
times per hour. Sauna shall be provided with
intended ventilations as required per the local
code authorities.
K. LIGHT
Wall-mounted, vapor-proof type lighting
can be used at minimum 6" (150 mm) from
ceiling, can be placed lower in room. Heat may
accelerate wear on lighting, for longest lasting
installation, place lights lower in the sauna
away from heater (under benches is ideal).
L. ACCESSORIES
bucket, ladle and thermometer are essential.
Thermometer should be placed over the
Sauna heater, 6" (150 mm) from ceiling, for
correct temperature reading. Thermometers
may require calibration before use for
accurate readings. Other accessories such
as hygrometer, sand timer, brushes, etc. are
available.
M. MAINTENANCE INSTRUCTIONS
are included at the end of this manual.
N. WARNING SIGNS
are furnished with Sauna heater. The metal
"CAUTION" sign should be fastened to wall,
close to heater, in a visible place. The metal
"WARNING" sign should be fastened outside,
to the Sauna room door.
WARNINGS!
Do not smoke, use alcohol, or exercise in the sauna!
Do not exceed 30 min. in the sauna at one time, as
excessive exposure can be harmful to health. The
sauna should not be used as an endurance test!
Persons with poor health should consult their
physicians before using the sauna!
Avoid fire, do not place any combustible material
over the sauna heater (towels, bathing suits,
wooden bucket or dipper)!
Use only clean tap water on the stones – do not
use pool, spa, or well water, as chlorine gas can
be produced and the heating elements can be
damaged!
Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above
the normal body temperature of 98,6ºF (37ºC).
The symptoms of hyperthermia include an increase
in the internal temperature of the body, dizziness,
lethargy, drowsiness, and fainting.