Installation and operation
2. Press the '+' key to increase the temperature and the '-' key to decrease the
temperature.
3. Finally, press the 'SET' key to confirm the setting.
Operating Time Change
1. Press the 'SET' key to change the operating time setting.
The time may be set in the range of 0–24 hours.
2. Change the operating time hours using the '+' or '-' keys.
3. Finally, press the 'SET' key to confirm the setting.
4. Press the 'SET' key to change the minutes setting.
5. Finally, press the 'SET' key to confirm the setting.
When the set time elapses, an acoustic signal will sound and the appliance will
switch off.
Time Remaining to Switching On
1. Press the 'SET' key to set the remaining time to switching on.
2. Using the '+' or '-' keys, select the desired time and, as long as the time indicator
flashes, press the 'SET' key.
The appliance will switch on after the pre-set remaining time to switching on.
NOTE!
The default setting for this function is 00:00. The remaining time to switching on
can be set in the range of 0–24 hours. This setting can only be made for a single
day and cannot be permanently stored or set as standard.
Only hours can be set for this setting, with no option to set minutes.
Example of the setting:
Time remaining to switching on: 1 hour
Temperature: 80˚C
Operating time: 6 hours 30 minutes
The appliance starts heating up after 1 hour. The water heats up to a pre-set
temperature of 80˚C. When this temperature is reached, a countdown begins for
the set time of six and a half hours. During the six and a half hours, the
temperature in the water tank remains constant at 80˚C (±3˚C).
When the temperature in the water tank drops by 3˚C, the appliance reheats the
water to the set temperature until the set time has elapsed.