8.9 Flange forces and torques

If not all loads reach the maximum permissible value stated in the
tables after fig. 10, one of these values may exceed the normal
limit. Contact Grundfos for further information.
Y-direction: Inlet/outlet
Z-direction: Direction of chamber stack
X-direction: 90 ° from inlet/outlet
Fig. 10 Flange forces [F] and torques [M]
Force limits
Flange
ANSI
DN
[in]
[mm]
1/
25/32
1 1/4
1 1/2
40
2
50
2 1/2
65
3
80
4
100
Torque limits
Flange
ANSI
DN
[in]
[mm]
1/
25/32
1 1/4
1 1/2
40
2
50
2 1/2
65
3
80
4
100
16
Pump
Cast iron pump housing
Force,
Type
Y-direction
Z-direction
[lb]
1s-5
76
10
93
15, 20
127
32
156
45
211
64
282
Pump
Cast iron pump housing
Torque,
Type
Y-direction
Z-direction
[ft-lb]
1s-5
221
10
295
15, 20
332
32
369
45
240
64
277
CR -
Force,
Force,
Force,
X-direction
Y-direction
[lb]
[lb]
89
72
105
84
131
114
177
143
173
190
228
253
CR -
Torque,
Torque,
Torque,
X-direction
Y-direction
[ft-lb]
[ft-lb]
129
92
203
148
240
184
258
221
295
406
350
461
CRI, CRN -
Stainless steel pump housing
Force,
Force,
Z-direction
X-direction
[lb]
[lb]
[lb]
152
177
143
185
211
169
253
261
228
312
354
287
421
346
379
565
455
506
CRI, CRN -
Stainless steel pump housing
Torque,
Torque,
Z-direction
X-direction
[ft-lb]
[ft-lb]
[ft-lb]
443
258
184
590
406
295
664
479
369
738
516
443
479
590
811
553
701
922