Electrical Connection; Installation - STEINEL Professional IR Quattro HD-2 COM1 Manual

Table of Contents

Advertisement

Available languages

Available languages

Product components (Fig. 3.3, Fig. 3.6)
A Surface-mounted surround
B Load module
C Connecting terminal
D Sensor module
E Reach adjustment
Detection zone (Fig. 3.7)

4. Electrical connection

The mains supply lead is a multiple-core
cable (max. conductor Ø 2.5 mm):
L
= Phase conductor (usually black
or brown)
N
= Neutral conductor (usually blue)
PE
= Protective-earth conductor
(usually green/yellow)
= Switched phase conductor
(usually black, brown or grey)
S
= Switch
B0/B1 = Floating relay for controlling
HVAC
Cable length between sensor and button
< 50 m.
Important: Incorrectly wired connections
will produce a short circuit later on in the
product or fuse box. In this case, you
must identify the individual cables and
re-connect them.
Connect the mains power supply lead
COM1 (Fig. 4.1/4.4/4.7)
Connect the mains power supply lead
COM2 (Fig. 4.2/4.5/4.8)
Connect the mains power supply lead
BT IPD (Fig. 4.3/4.6/4.9)

5. Installation

• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting loca-
tion, taking the reach and presence
detection into consideration (Fig. 3.7)
Mounting procedure
• Switch off power supply.
(Fig. 4.1/4.2/4.3)
Concealed mounting
• Connect to mains power supply.
(Fig. 5.1)
• Fit load module and screw into place.
(Fig. 5.2)
• Fit magnetic sensor module. (Fig. 5.3)
• Switch ON power supply. (Fig. 5.3)
Surface mounting
• Mark drill holes and drill. (Fig. 5.4)
• Screw load module into place. (Fig. 5.5)
• Connect to mains power supply.
(Fig. 5.6)
• Fit surface-mounted surround. (Fig. 5.7)
• Fit magnetic sensor module. (Fig. 5.8)
• Switch ON power supply. (Fig. 5.8)
• Make settings.
(➜ „6. Function and settings")
6. Function and settings
Factory settings
The factory settings are activated when
the presence detector is put into operation
for the first time as well as after resetting
by the app.
The following factory settings are
provided:
Sensitivity:
- 18 -
Sensitivity A: 100%
Sensitivity B: 100%
Sensitivity C: 100%
Sensitivity D: 100%