8. TECHNICAL DATA

MultiPlus
PowerControl / PowerAssist
Transfer switch (A)
Minimum PowerAssist current (A)
INVERTER
Input voltage range (V DC)
Output
Cont. output power at 25°C (VA) (3)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
Zero load power in search mode (W)
CHARGER
AC Input
Charge voltage 'absorption' (V DC)
Charge voltage 'float' (V DC)
Storage mode (V DC)
Charge current house battery (A) (4)
Charge current starter battery (A)
Battery temperature sensor
GENERAL
Programmable relay (5)
Protection (2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
120 V AC-connection
Weight (lbs)
Dimensions (hxwxd in inches)
STANDARDS
Safety
Emission / Immunity
12/2000/80-50
24/2000/50-50
120V
Yes
50
8,5
9,5 – 17
Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
2000
1600
1450
1100
4000
92
9
3
Input voltage range: 95-140 VAC
Input frequency: 45 – 65 Hz
14,4 / 28,8
13,8 / 27,6
13,2 / 26,4
80
Operating temp. range: -40 - +65°C (fan assisted
cooling) Humidity (non condensing) : max 95%
Material & Colour: aluminium (blue RAL 5012)
Protection category: IP 21
screw-terminals 6 AWG (13mm²)
20.5 x 10.0 x 5.0 (520 x 255 x 125 mm)
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 55014-2, EN 61000-3-3
120V
Yes
50
8,5
19 – 33
2000
1600
1450
1100
4000
94
11
4
Power factor: 1
28,8
27,6
26,4
50
4
yes
yes
a - g
Bolts M8
25 (13 kg)