Installation Instructions
DO NOT attempt to increase the power nor rated heat load specified by the
manufacturer.
Check the rated heat pressure with gas meter and a stop watch. Measure
exactly the amount of gas flowing per unit of time the appliance is consuming
with maximum power.
Compare the measured value with data on consumption in section 'Technical
Specifications', Table 3. Admissible deviation is ±5%.
Check the gas supply pressure observing indication in section 7.3
„Maintenance / Gas Supply Pressure Check".
Resetting to Other Type of Gas / Required Adjustments
The appliances are set to the following gas type:
Check the type of the supplied gas in the country of installation, and, if needed,
reset the appliance to the other gas type.
Tables 1 and 2 in section 'Technical Specifications' provide, depending on the
country of installation:
– what gas types may be used to power the appliance;
– nozzles and settings for each gas type that is used.
The number provided in Table 2 for proper nozzles is pressed on nozzles' bodies.
In order to adapt the appliance to the gas type, with which it may be effectively
operated, collect data from Table 2 and perform the following actions:
– exchange main burner's nozzle (UM)
– fit main burner air controller within the distance A
– exchange ignition burner's nozzle (UP)
– perform air adjustment of ignition burner (if needed).
2834431
natural gas E
EN
25 / 36