Motor Check; Start Relay - Cornelius Quantum 1000 Service Manual

500, 700, 1000, 2000 - series continuous flow icemaker
Hide thumbs Also See for Quantum 1000:
Table of Contents

Advertisement

Continuous Flow Icemaker Service Manual
M
C
OTOR
HECK
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
!
WARNING:
The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low readings must
be used. The start relay cover must be removed.
If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test, replace
gearmotor.
S
R
TART
ELAY
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
!
WARNING:
1. Check between "2" and "4" on relay (with relay unplugged). If there is continuity replace the relay, as the relay
contacts should be open.
2. Check between "3" and "4" on relay, if no continuity replace the relay.