Cleaning And Sanitizing; Icemaker Cleaning And Sanitizing Procedures; Maintenance; Monthly - Cornelius Quantum 1000 Service Manual

500, 700, 1000, 2000 - series continuous flow icemaker
Hide thumbs Also See for Quantum 1000:
Table of Contents

Advertisement

I
C
CEMAKER
LEANING AND
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
!
WARNING:
Do not use any of the ice made during cleaning operations.
Clean and sanitize ice storage area when cleaning icemaker.
1. Turn machine off.
2. Shut off water supply.
3. Remove ice from storage bin.
4. Mix approved cleaner (2 gallons as directed). Recommended cleaner: Nu-Calgon liquid ice machine cleaner.
Mixture: 3-1/3 ounces per gallon of water.
!
WARNING:
Cleaner must be safe for stainless steel. NO EXCEPTIONS.
5. Clean auger/diverter assembly and ice transition/drop tube in a sink using cleaner mixture and reinstall in ice-
maker. Using cleaner, wipe down the dispense tray.
6. Turn machine on and add cleaner solution to water level control until 2 gallons have been used.
7. Turn on water supply and run machine for 15 minutes.
8. Turn off machine and remove all ice.
9. Sanitize using household liquid bleach (50 ppm chlorine). Mixture: 1 fluid ounce per gallon room temperature
water. 2 minute exposure time.
10. Sanitize auger/diverter assembly and ice transition/drop tube in a sink using sanitizing solution and reinstall in
icemaker. Using sanitizer, wipe down the dispense tray.
11. Fill icemaker with sanitizer by slowly pouring solution into water feed reservoir until full. Solution will drain
through overflow tube. Do not run machine. Allow to air dry.
12. If icemaker is used in conjunction with ice dispenser or storage bin, follow manufacturer's recommended clean-
ing instructions at this time.
M
AINTENANCE
Preventive maintenance can increase the trouble free life of your icemaker. Many authorized service agencies offer
service contracts for your icemaker. Contact your local distributor for further information.
M
ONTHLY
1. Clean the condenser. Use a brush, vacuum cleaner or blow from inside with air or CO
2. Inspect water feed reservoir at lease once a month until a definite pattern for cleaning and sanitizing has been
established.
Q
UARTERLY
This is the maximum period of time between cleaning and sanitizing the icemaker. In addition to recommended
monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been established, unit must be
cleaned and sanitized.
© 2004-2011, IMI Cornelius Inc.

CLEANING AND SANITIZING

S
ANITIZING
Continuous Flow Icemaker Service Manual
P
ROCEDURES
- 7 -
gas.
2
Publication Number: 630460174SER

Advertisement

Table of Contents
loading

Table of Contents