8.2.4 Specifications of standard wiring components
8.2.5 To connect the electrical wiring to the indoor unit
FTXP20~35M5V1B9
Split system air conditioners
4P519439-7S – 2021.12
b
a
a Stranded conductor wire
b Round crimp-style terminal
▪
Use the following methods for installing wires:
Wire type
Single-core wire
Stranded conductor wire
with round crimp-style
terminal
▪
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Component
Interconnection cable (indoor↔outdoor)
Electrical work should be carried out in accordance with the installation manual
and the national electrical wiring rules or code of practice.
1 Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
Installation method
c b
A
A´
a
a Curled single-core wire
b Screw
c Flat washer
c b
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
1-3
8
Electrical installation
|
AA´
c
a
a
b
c
B
4-core cable 1.5 mm²~2.5 mm²
and applicable for 220~240 V
H05RN-F (60245 IEC 57)
Installer reference guide