6
|
Unit installation
6 Unit installation
In this chapter
6.1 Preparing the installation site
6.1.1 Installation site requirements of the indoor unit
Installer reference guide
18
6.1
Preparing the installation site ................................................................................................................................................
6.1.1
6.2
Opening the indoor unit .........................................................................................................................................................
6.2.1
To remove the front panel.....................................................................................................................................
6.2.2
To re-install the front panel ...................................................................................................................................
6.2.3
To remove the front grille......................................................................................................................................
6.2.4
To re-install the front grille ....................................................................................................................................
6.2.5
6.2.6
To open the service cover......................................................................................................................................
6.3
Installing the indoor unit ........................................................................................................................................................
6.3.1
6.3.2
To install the mounting plate.................................................................................................................................
6.3.3
To drill a wall hole ..................................................................................................................................................
6.3.4
To remove the pipe port cover ..............................................................................................................................
6.3.5
To provide drainage ...............................................................................................................................................
Choose an installation location with sufficient space for carrying the unit in and out
of the site.
Do NOT install the unit in places often used as work place. In case of construction
works (e.g. grinding works) where a lot of dust is created, the unit MUST be
covered.
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
INFORMATION
Also read the precautions and requirements in the
4
precautions" [
INFORMATION
The sound pressure level is less than 70 dBA.
▪
Air flow. Make sure nothing blocks the air flow.
▪
Drainage. Make sure condensation water can be evacuated properly.
▪
Wall insulation. When conditions in the wall exceed 30°C and a relative humidity
of 80%, or when fresh air is inducted into the wall, then additional insulation is
required (minimum 10 mm thickness, polyethylene foam).
▪
Wall strength. Check whether the wall or the floor is strong enough to support
the weight of the unit. If there is a risk, reinforce the wall or the floor before
installing the unit.
5].
18
18
19
19
20
20
22
22
22
23
23
23
23
24
24
"2 General safety
FTXP20~35M5V1B9
Split system air conditioners
4P519439-7S - 2021.12