18.1.3 Specifications of standard wiring components

FXKQ-A
VRV system air conditioner
4P747548-1 – 2023.11
Use the following methods for installing wires:
Wire type
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
Stranded conductor wire
with round crimp-style
terminal
Tightening torques
Wiring
Power supply cable
Transmission cable
(indoor↔outdoor)
User interface cable
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Power supply of the product
Voltage
Frequency
Phase
18
Installation method
c b
A
c
a
a Curled wire (single-core or twisted stranded
conductor wire)
b Screw
c Flat washer
c b
B
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
Screw size
M4
M3.5
220~240 V/220 V
Electrical installation
|
AA´
a
a
b
c
Tightening torque
(N•m)
1.3~1.6
0.79~0.97
50/60 Hz
1~
Installer and user reference guide