Installation; Pre-Installation; Freight Damage Claim; Counter - Cornelius UCR 700 Series Installation & Service Manual

Ucr 700 series continuous flow icemaker
Table of Contents

Advertisement

P
-I
RE
NSTALLATION

FREIGHT DAMAGE CLAIM

The delivery of your equipment (Frieght Company, Distributor, or dealer) is responsible for loss or damage of your
shipment. All claims must be filed with the deliverer of your equipment. Please follow the steps below to determine
if your shipment is satisfactory or if a claim must be filed:
1. Check the number of products delivered against the number of products listed on the delivery receipt.
Should the totals not match, have the driver note all errors on both copies and both you and the driver sign
and date said notation.
2. Inspect all cartons for visible damage. Open and inspect as required before the driver leaves and have him
or her note any damage on the receipts. All damaged claims must be inspected within 15 days of delivery.
Notify your carrier immediately if concealed damage is found after delivery.
3. Should concealed damage be found when the product is unpacked, retain the packing material and the
product and request an inspection from the deliverer.
4. All claims for loss or damage should be filed at once. Delays in filing will reduce the chance of achieving a
satisfactory resolution to the claim.

COUNTER

1. A flat and level counter space sufficiently strong to support the weight of the Dispenser and the Icemaker.
The Icemaker may be installed on the left or the right side of the Dispenser.
2. General Requirements:
A. The front of the Icemaker must be free of obstructions.
B. Allow a 4--inch minimum clearance between exaust side of the Icemaker and adjacent equipment.
C. A louvered front panel (12--inches X 12--inches) aligned with the air inlet of the Icemaker and adequate
ventilation (1.5 Sq. feet opening) in the counter for exaust air.
D. A removable panel in the counter face (from 2--inches below the top of the counter to the floor, a mini-
mum of 19--inches wide) to allow removal of the Icemaker.

ELECTRICAL

Two separate 20 amp, 120VAC, 60 Hz electrical circuits.

DRAIN

One drain beneath the counter at floor level which will accomodate both the drain from the Icemaker and the
Dispenser.
I
NSTALLATION
1. Keep unit in the upright position, remove carton and pallet from the Icemaker and inspect for damage. If
any damage is found, file a claim with carrier immediately.
2. Locate startup card either on outside of container or on plastic liner. Fill in proper information and send one
to factory, and other copy to distributor. Postage is prepaid.
3. Install the Dispenser first, following installation instructions supplied with the Dispenser.
4. Remove the two hole plugs from the side of the dispenser.
© 2001-2012, IMI Cornelius Inc.
UCR 700 Series Continuous Flow Icemaker Installation/Service Manual

INSTALLATION

- 6 -
Publication Number: 630460154