FUnCTIon SETTInG InDooR UnIT WITH InTEGRATED WATER TAnK
INDOOR UNIT WITHOUT INTEGRATED WATER TANK
5�2�4 Cooling logic
A
Frequency
B
Plant water temperature
max
min
Min and max depend on the logic corresponding to the active mode (cooling) and the configuration of the unit.
PT1, 5, 6: Plant temperature probe. This depends on the setting of "SRI"
p. 17
"ESP"
: SUMMER setpoint (Cooling)
If the external climate control is active, the reference setpoint is not PF22, but the dynamically calculated setpoint. View
chapter "Dynamic set adjustment"
p. 18
"EHY"
: SUMMER hysteresis (2.5 °C)
The function is inhibited by the simultaneous request for domestic hot water (which higher priority) but the priority can be
reversed for 90 minutes ("FH"
40
A
ESP
p. 43
.
p. 21
) by pressing the Fast Heating button
C
Adaptive control logic
C
ESP + EHY
PT1 o PT5 o PT6
p. 21
B