TESY MultiThermica User's And Installer's Manual page 21

Residential heat pump control panel
Table of Contents

Advertisement

OTS
Setting: Differential for climate control
#
Units of measure: °C
#
Minimum: 0
#
Maximum: 40
#
Setting: 5
#
SIL
Select: Silent
#
NO: disabled (default)
#
YES: enabled
#
FH
Setting: Fast heat function
#
NO: disabled (default)
#
YES: enabled
#
ALC
Setting: Autlock display
#
NO: disabled
#
YES: enabled (default)
#
SRI
Select: system regulation probe
#
PT1: plant (circuit breaker or inertial tank)
#
PT5: system delivery
#
PT6: system return (default)
#
PI4
Setting: PI4 input options
#
SEA: cooling/heating selection
#
LEG: ANTI-LEGIONELLA (Default)
#
PI5
Selects: ON/Standby from digital input
#
STO: Standby when open
#
STC: Standby when closed
#
SCE: Cooling/heating selection
#
PI6
Setting: PI6 input options
#
NO: contact normally open
#
FTV: minimum photovoltaic delay
#
TSD
Setting: Probe displayed
#
PT4: domestic hot water
#
PT5: system delivery
#
PTI: plant (circuit breaker or inertial tank)
#
PT8: outside air
#
OS1
Setting: Probe Offset PT1
#
Units of measure: °C
#
Minimum: -12,5
#
Maximum: 12,5
#
Setting: 0
#
OS4
Setting: Probe Offset PT4
#
Units of measure: °C
#
Minimum: -12,5
#
Maximum: 12,5
#
Setting: 0
#