Schematic Diagram With Sanitary Hot Water Storage And Heating Generator; Enable Domestic Hot Water Production - TESY MultiThermica User's And Installer's Manual

Residential heat pump control panel
Table of Contents

Advertisement

FUnCTIon SETTInG InDooR UnIT WITHoUT InTEGRA TED WA TER T AnK
INDOOR UNIT WITHOUT INTEGRATED WATER TANK
4�3�2 Schematic diagram with sanitary hot water storage and heating generator
A
Plant
B
Indoor unit Indoor Unit Without Integrated Water Tank
C
outdoor unit
1�
Plate exchanger
2�
Plant temperature probe (PT1)
3�
Expansion vessel
4�
3-bar safety valve
5�
Network water filter
6�
Flexible connections
7�
Shut-off valves
8�
Plant drain cock
9�
Automatic plant filling assembly
10�
Expansion vessel
11�
PP1 primary circulation pump
Domestic hot water temperature check
The domestic hot water temperature is controlled by the PT4 probe that must be positioned in the domestic hot water stor-
age tank.
4�3�3 Enable domestic hot water production
The domestic hot water function must be enabled by parameter "SCE" 
30
12�
Electric heating element
13�
Heat generator (boiler)
14�
Instant domestic hot water preparation storage
15�
Thermostatic mixer
16�
Domestic hot water consumers
17�
Domestic hot water recirculation pump
18�
Check valve
19�
Safety valve
20�
Domestic hot water tank temperature probe (PT4)
21�
Separator
22�
3-way on/off valve PV1
23�
Flow switch (differential pressure switch)
24�
Dirt separator