SHY
Set: SANITARY hysteresis
#
Units of measure: °C
#
Minimum: 1
#
Maximum: 10
#
Setting: 2
#
LSP
►
Set: ANTI-LEGIONELLA setpoint
#
Units of measure: °C
#
Minimum: 30
#
Maximum: 90
#
Setting: 60
#
►
LTI
Enable: interval between ANTILEGIONELLA cycles
#
0: off (default)
#
Unit of measurement: days
#
Minimum: 0
#
Maximum: 30
#
Setting: 0
#
LTM
►
Sets: anti-legionella cycle time
#
Unit of measurement: hours
#
Minimum: 1
#
Maximum: 12
#
Setting: 2
#
►
LTO
Set: ANTILEGIONELLA cycle timeout
#
Unit of measurement: hours
#
Minimum: 1
#
Maximum: 24
#
Setting: 5
#
HIE
►
Enable: auxiliary heater management
#
NOT: not present
#
INT: in integration (default)
#
COM: switching
#
CAL: boiler
#
►
HIS
Set: Maximum water temperature for pdc function
#
Units of measure: °C
#
Minimum: 20
#
Maximum: 55
#
Setting: 53
#
►
HOR
Set: outside temperature heating element activation in WINTER
#
Units of measure: °C
#
Minimum: -30
#
Maximum: 30
#
Setting: -15
#
HOS
►
Enable: external temperature activation heater SANITARY
#
Units of measure: °C
#
Minimum: -30
#
Maximum: 30
#
Setting: -15
#
MEnU STRUCTURE
19