Short circuit safety 4.4.2 Residual current safety Internet access 4.5.1 Wi-Fi 4.5.2 Installation Mounting Connection 5.2.1 Cable connection 5.2.2 Bottom cable entry 5.2.3 Back cable entry Reassemble Configuration Create a Charge Amps Partner Account Connect Charge Amps Halo OCPP 1.6J version...
Page 3
English 6.2.1 Connect via Charge Amps Halo Wi-Fi access point 6.2.2 Connect via LAN 6.2.3 Local management interface settings Connect Charge Amps Halo CAPI version 6.3.1 Connect via Charge Amps Halo Wi-Fi access point 6.3.2 Connect via LAN Cloud connectivity...
Page 4
Neglecting to follow and carry out the directions, instructions and safety precautions in this Installation Manual implies that any warranty provisions will be cancelled and that Charge Amps can reject any and all claims for compensation in connection with any injuries/damage or incidents – direct or indirect –...
English Safety WARNING: Read all instructions before installation! • The product must only be installed by a qualified electrician in accordance with the Installation Manual. • Make sure to switch the power off at the main switch before installation or service. •...
Page 6
English • Never attempt to disassemble the product in any way other than what is described in the Installation Manual. • Make sure that all terminal screws are securely fastened before reattaching the charger unit. • Make sure that all terminal screws are securely fastened before reattaching the front cover.
English 2 Technical data Charging mode Mode 3 EV power supply identifier Metering 1 to 3 phase voltage, current and power Vehicle connector Type 2, 7.4/11 kW Rated voltage (U 230/400 V Rated insulation voltage (U 250/400 V Rated impulse withstand voltage 4 kV Rated frequency (f 50 Hz...
Page 8
English Pollution degree Electromagnetic compatibility Environment B Operating temperature -35°C to +45°C Altitude 0 m to 2000 m IP code Main unit: IP66 Vehicle connector: IP44 IK code IK10 Mechanical resistance High Dimensions (W x D x H) Main unit: 262 x 159 x 203 mm Vehicle connector: 81 x 125 x 88 mm Cable length 7.5 m...
Page 9
Type: 802.11 b/g/n Range: 2400-2500 MHz Max output: 20/17/14 dBm@802.11 b/g/n Communication protocol OCPP 1.6J (valid for Charge Amps Halo with product number: 130577, 130578, 130800, 131134, 131114 and 131133) CAPI (valid for Charge Amps Halo with product number: 100307, 100308, and...
English 3 Product overview Centre light and RFID reader 230 V socket-outlet (some models only) Ring light Back cover Front cover Vehicle connector holder* Cable entry: fixed charging cable Vehicle connector* Wi-Fi antenna Incoming power cable entry *Comes in different versions Data cable entry...
English 3.1 Package contents Terminal connector RFID tag Cable fitting Wi-Fi antenna Vehicle connector holder...
Page 12
English Charge Amps Halo Accessories: • 1x RFID tag • 1x Five-pin terminal connector for feed current (comes in different versions). • 2x Cable fitting for power and data. • 1x Wi-Fi antenna • 1x Vehicle connector holder (comes in different versions) •...
4.2 Materials provided by the installer • 3 x 5 mm flat head stainless screws type A2 or A4 with associated plugs (if required) for mounting of Charge Amps Halo • 2 x 3.5 mm screws with recessed head for wall mounting of the Vehicle connector holder •...
N.B: Make sure to always use sealant if installing in an outdoor environment or on an uneven surface. • If possible, do not mount Charge Amps Halo in direct sunlight. • Make sure the wall can support the product weight.
Make sure the installation for Charge Amps Halo is properly fused: • Charge Amps Halo 1-phase 3.7 kW: 16 A, Curve B or C MCB*. • Charge Amps Halo 3-phase 11 kW: 16 A, Curve B or C MCB*.
Charge Amps Halo. 4.5.1 Wi-Fi Once the power is switched on, Charge Amps Halo will provide a Wi-Fi access point which is available for 10 minutes. You can use the Wi-Fi access point to connect Charge Amps Halo to the Wi-Fi network of the facility.
Halo OCPP version. N.B: Max. outer diameter of the ethernet cable is 4-8 mm. It is possible to connect Charge Amps Halo via an ethernet cable with following specifications: • The connector of the ethernet cable must be of short type.
Page 18
English 4. Remove all connected terminal blocks/connectors from the circuit board. 5. Place the circuit board on a safe place, not directly on the ground.
Page 19
English 6. Mark and drill mounting holes on the wall for the Charge Amps Halo accordnig to the dimensions in the drawing below*. The marked area is the sealing area that puts pressure on the wall. Make sure this area is flat and clean to avoid water leakage.
Page 20
Follow the instructions in chapter ”5.2.3 Back cable entry” for more information. (Mounting screws are not included in the packaging for Charge Amps Halo).
Page 21
8. Mark and drill mounting holes on the wall for the Vehicle connector holder. Place the holes for the Vehicle connector holder approximately 30 cm to the right of Charge Amps Halo. N.B: Note that the Vehicle connector holder comes in two different versions.
5.2.1 Cable connection N.B: There are two options for cable entry, via the bottom or back side of Charge Amps Halo. Only insert the cable through the specified cable entries. Electrical conditions in the facility and cable lengths may require a higher cross-sectional area to meet the triggering conditions.
2. Mount the external Wi-Fi antenna. 3. Insert the ethernet cable through the data cable entry*. N.B: Max. outer diameter of the ethernet cable is 4-8 mm. * Only applicable for Charge Amps Halo with product number: 130577, 130578, 130800, 131134, 131114 and 131133.
Page 24
English 4. Strip the power cable (15-20 cm) and insert through the power cable entry. 5. Retighten the cable entry nut (2 Nm).
Page 25
English 6. Connect the conductors to the 5-pin terminal block according to your supply network: • TN/TT one phase connection: it is recommended to connect all phases in a one-phase installation since it will optimize load balancing functionality. • TN/TT three phase connection: connect all phases. TN/TT •...
IMPORTANT: Always use sealant when mounting Charge Amps Halo to the wall! When pulling the cables from the back side of Charge Amps Halo, please note that the wall sealing comes in two different versions: • Version 1: comes with a separate power cable entry and data cable entry.
Page 27
English 1. Mount the external Wi-Fi antenna. 2. Strip the power cable (15-20 cm).
Page 28
3. Insert the power cable and ethernet cable through the specified cable entry. Note that the cable entry will vary depending on version of wall sealing. N.B: LAN connection is only applicable for Charge Amps Halo OCPP version. N.B: Max. outer diameter of the ethernet cable is 4-8 mm.
Page 29
English 4. Connect the conductors to the 5-pin terminal block according to your supply network: • TN/TT - one phase connection: it is recommended to connect all phases in a one-phase installation since it will optimize load balancing functionality. • TN/TT - three phase connection: connect all phases. TN/TT •...
English 5.3 Reassemble 1. Refit the terminals in the front cover. 5-pin terminal block for incoming power supply 3-pin terminal block for socket-outlet 6-pin terminal block for charging cable Ethernet connector (some models only) Wi-Fi antenna cable...
Page 31
• All O-rings around the fastening screws are in place. • No cables are pinched. • All cables are properly seated. • The front cover is mounted with Charge Amps logo in an upright direction. 3. Tighten the four H4 Allen head screws with a torque of 1.5–2.0 4.
Charge Amps Halo comes with two different communication protocols, OCPP 1.6J or CAPI. Follow the instructions for configuration based on the version of your Charge Amps Halo: • Charge Amps Halo with product number 130577, 130578, 130800, 131134, 131114 and 131133 with communication protocol OCPP 1.6J: follow chapter 6.2.
Before starting the configuration process, make sure you have access to: • The serial number for Charge Amps Halo (can be found in the documentation included in the packaging). • The PIN code for Charge Amps Halo (can be found in the documentation included in the packaging).
”Local management interface settings”. 6.2.2 Connect via LAN 1. Make sure that Charge Amps Halo is connected to the local network via an ethernet cable of one the RJ45 port. 2. Using a smart phone, tablet or computer, open a new window in the web browser.
When Charge Amps Halo is connected to a cloud service, all management of RFID-tags is handled in the cloud. If Charge Amps Halo is to be operated offline, without a connection to a cloud service, management of RFID tags can be handled in the local management interface.
Before starting the connection process, make sure you have access to: • The serial number for Charge Amps Halo (can be found in the documentation included in the packaging). • The PIN code for Charge Amps Halo (can be found in the documentation included in the packaging).
N.B: The Charge Amps Halo Wi-Fi access point is deactivated if the RJ45 ports is actively connected. Once the power is switched on, Charge Amps Halo will provide a Wi-Fi access point which is available for 10 minutes. Connect to...
Please download Charge Amps App for full control, adjusting settings and enabling smart charging and scheduling. Charge Amps App Please create an account in the Charge Amps Cloud to configure, control and manage your charger via our web interface. My charge space https://my.charge.space/...
The power supply to the charger must be isolated before dismounting starts. 1. Perform a factory reset of Charge Amps Halo before powering it down. Contact the supplier before performing this action. 2. Turn the power off at the main switch.
English 10 Product support and service If you have any questions or problems with the product, support is always available. To find answers to your questions most quickly: Read through the User Manual to check whether your questions are answered there. If your question is not answered, please: 1.