4. S31501 Sensor Function

(1) Reed Switch
Detect the opening and closing state of the reed switch.
Open: report 1
Close: report 0
➢The reed switch needs to be fixed when used, such as the double sided tape.
(2) Temperature and Humidity Sensor
Detection of temperature and humidity in ambient air.
Temperature unit: 0.01°C, signed value.
Humidity unit: 0.5%
(3) Glass Break
No broken glass detected: report 0
Broken glass detected: report 1

5. Set up Instruction

--- On/Off ---
Power on/Turn on
Turn off
(Reset to factory setting)
Note
Insert batteries.
Press function key until green indicator flashes once.
Press the function key for more than 8 seconds, and the green indicator
light will flash continuously.
Release the key after the flash starts, and the device will automatically
shut down after the flash ends.
(Indicator light display: the indicator light will flash once every 2s to
prompt the current pressing duration)
On/off interval is suggested to be about 10 seconds to avoid the
interference of capacitor inductance and other energy storage
components.