Figure 3.15 Example of half-populated configuration
5. Repeat steps 2 through 4 for all remaining drives.
Drive installation is complete. Reinstall the IOM(s).
Reinstalling the I/O Module(s)
Once rack installation is complete, the user may reinstall the IOM(s) into the
VDS41022 expansion enclosure.
ESD-DEVICE: Follow proper anti-static guidelines when handling the modules, e.g.
wrist strap, ESD mat, etc.
CAUTION: In single IOM configurations, a blank canister is required in the unoccupied
I/O option slot B to maintain proper system cooling. Contact a Viking Enterprise
Solutions™ sales representative for more information on ordering a blank canister for
a single IOM configuration.
CAUTION: To avoid damage to components inside the IOM or damage to the
connectors, install the module in the correct orientation (with the release tabs at the top
of the I/O option slot). Ensure the edge fingers properly align with the baseboard
connectors before installing the IOM. Never force a module into the slot.
1. The rails should still be extended in the serviceable position and the
enclosure's top cover still removed.
2. Identify the edge fingers on the bottom of the IOM and the connectors inside
I/O option slot A. (Slot A is on the right when viewed overhead from the front of
the enclosure.) The edge fingers on the IOM must properly mate with the
connectors in the I/O option slot. The RJ45 port should be at the bottom upon
installation and the release tabs should be at the top as shown in Figure 3.16.
48
Viking Enterprise Solutions™ Proprietary Information
ONYX Series Harware Guide
Document CTC-DOC-003005