Countertop Icemaker IMD Series Installation Manual
Motor Check
The resistance readings on the windings will be between 5 to 25 ohms. A meter capable of these low
readings must be used. The Start Relay cover must be removed.
If no continuity on start or run winding test, replace stator. If continuity on grounded motor test, replace
stator.