Water Level Control; How Water Level Control Works; Purpose Of Water Level Control; To Replace Water Level Control - Cornelius IMD Series Installation Manual

Cornelius countertop icemaker installation manual
Hide thumbs Also See for IMD Series:
Table of Contents

Advertisement

H
W
L
OW
ATER
EVEL
When water is introduced through the inlet fitting the float rises. The float pushes against a lever which in
turn forces the poppet assembly against the inlet fitting valve seat which seals the water off, (see FIG-
URE 4). Before the water inlet is sealed the safety switch is operated. In the event of a water failure the
float would drop down and operate the safety switch to shut off the machine.
If water level control will not shut off and seal at level as indicated, be sure inlet pressure does not
exceed recommended factory operating range.
Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted
when unit was installed or relocated. If, however, the control becomes inoperative, repair or replace.
See Start-Up Adjustment.
P
W
URPOSE OF
ATER
1.
To automatically maintain proper water level in the evaporator when unit is running and making ice.
2.
A safety switch is operated in the event of an interruption in water supply. The switch shuts off the
electrical power to the icemaker and its refrigeration system. Switch will reset as soon as cause of
water failure has been corrected and proper water level in icemaker has again been reached.
3.
The transparent bowl not only provides a visible check of water level, but also is a good guide to the
internal conditions which exist within the icemaker assembly itself. (See Cleaning Procedure).
T
R
W
O
EPLACE
ATER
1.
Shut off the water supply. Shut off the main power switch or unplug the ice dispenser from electrical
outlet.
2.
Remove the flexible tubing from bottom of water level control and drain water from water level con-
trol and evaporator.
3.
Remove flexible tubing at bottom of water level bowl connected to the overflow.
4.
Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.
5.
Remove wing nut holding water control to its mounting bracket. Control can be removed by lifting
straight up.
T
R
W
O
EPLACE
ATER
1.
Shut off main power switch or unplug the ice dispenser from electrical outlet.
2.
Unplug molex connector connecting switch to electrical box.
3.
Remove the 2 screws anchoring the water level safety switch to the bottom of the water level control
mounting bracket.
I
L
C
CE
EVEL
ONTROL
The ice level control assembly is secured to the top of the ice storage container cover. The cover is
secured to the storage container with four screws. The level control switch is operated by a plate assem-
bly located beneath the diaphragm. When the plate assembly is down due to lack of ice in storage con-
tainer, electrical impulse is sent to compressor, starting the ice making cycle. As ice level increases in
storage container, the plate assembly is pushed up. When storage container is full, it de-actuates the
switch, stopping the compressor and ice making cycle.
© 2004-2009, IMI Cornelius Inc.

WATER LEVEL CONTROL

C
W
ONTROL
ORKS
L
C
EVEL
ONTROL
L
C
EVEL
ONTROL
L
S
EVEL
AFETY
Countertop Icemaker IMD Series Installation Manual
S
WITCH
- 9 -
Publication Number: 638085277INS

Advertisement

Table of Contents
loading

Table of Contents