Vegator 532 Ex - Vega VEGATOR 256C Operating Instruction

Conductive electrodes
Table of Contents

Advertisement

4.2 VEGATOR 532 Ex

18
1 Ex-fuse T50 mA / 250 V
2 Mains fuse T 1 A / 250 V
3 Connection plan
4 Lockable screw
5 Potentiometer for switch point
adjustment for channel 1
6 LED output 1
Indicating and adjustment elements
Potentiometer
The switch point or the adaption to the
product conductivity can be adjusted via
potentiometer separately for each channel.
Use a small screwdriver to carry out the
adjustments on the potentiometer.
28
1
B
A
B
A
16
17
7 LED fault signal channel 1
8 Potentiometer for switch point
adjustment for channel 2
9 LED output 2
10 LED fault signal channel 2
11 LED supply voltage
12 Screw
13 Multiple plug
2
BR1
BR2
15
14
Control lamps
LED in the front plate indicate
operation, switching condition of the relay
outputs and fault signals.
Two yellow LED (6 and 9) for status
indication of the relay or transistor outputs
1 and 2 (LED lights = relay energizes,
transistor conductive, LED extinguished =
relay deenergizes, transistor blocked)
Two red LED (7 and 10) for failure
indication of channel 1 and 2 (LED lights =
channel interferred).
One green LED (11) for indication
operating voltage "on".
3
4
5
5
6
0
10
7
1
5
8
9
0
10
2
10
on
11
532 Ex
13
12
14 Soldering bridge for fault signal
adjustment channel 1
15 Soldering bridge for fault signal
adjustment channel 2
16 Selection switch mode A/B for
channel 1
17 Selection switch mode A/B for
channel 2
18 Transparent cover
Conductive measuring system
Set-up

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vegator 532 exVegator 631 ex

Table of Contents