Troubleshooting - Cornelius 1000 - Series Service Manual

500, 700, 1000, 2000 - series continuous flow icemaker
Hide thumbs Also See for 1000 - Series:
Table of Contents

Advertisement

NO POWER
Remote condenser
units only
Check electrical wiring in con
trol box for loose connec
tions.
Check for failed service
Remote condenser
switch or relay.
not running.
Check power to machine.
High pressure
Check electrical
Check power
switch open or
wiring in control box
to condenser.
cycling on and off.
for loose connections.
Discharge
Non-condensible
Too much
Condenser
king valve
in system.
refrigerant in
fan not
partially
system.
running.
closed.
Evacuate and
Check electrical circuit
Open
recharge system.
to fan motor.
valve
Clean condenser.
Check fan motor.
Low pressure switch open
or cycling on and off.
Remote condenser
Low on
units only
refrigerant.
Check for
LAC not operating
leaks.
properly (minimum
discharge pressure
180 lbs.).
Replace LAC valve,
evacuate and
recharge system.
TROUBLESHOOTING CHART - ICEMAKER NOT OPERATING
LOW WATER SAFETY
ICEMAKER RUNS BUT
SWITCH OPEN
DOES NOT MAKE ICE
Condenser fan running
but compressor not running
Check line voltage.
Check that water is turned on.
Check compressor winding
Check for restriction in water line.
& components.
Check incoming water pressure
(minimum 10 lbs.).
Check water safety switch.
Evaporator water tube
may have an air bubble.
Clear air bubble from
tube.
High suction pressure
(30 lbs. or above).
Head
TXV not
Pressure
operating
high.
properly.
Condenser
dirty or
Valve
Bulb
restricted.
stuck
loose.
open.
Replace
Clean
valve.
and
tighten.
Plugged
Restricted
Plugged or
Icemaker
liquid line
liquid line.
faulty TXV.
froze up.
dryer.
Check if
Replace
Check for
Replace
auger is
dryer.
kinks or
valve.
turning.
Evacuate
damage to
Evacuate
and
liquid line.
and
recharge
recharge
system.
system.
No
Check drive on
Check gears in
gearmotor.
gearbox.
ICEMAKER OPERATING BUT
SOFT ICE
Check bin switch
Yes
Clean all related
drain lines.
Low suction pressure
(20 lbs. or below).
Suction line
TXV bulb
not
lost charge.
insulated.
Bulb
Replace valve
uninsulated.
evacuate and
recharge.
Clean and
insulate.
IMPORTANT
Icemaker runs when reset
but problem has not been
found.
Continue checking for
overload as follows to
guard against future
problems
OVERLOAD GUIDE
ELECTRICAL
High or low voltage weak power lines can cause overloads on icemaker restarts
High running current. Check motor circuits and start relay - Auger delay failed.
ICEMAKER
Mechanical parts worn. Scored evaporator or auger. Worn thrust bearing.
Ice maker not turning off. Failed ice level control.
Over compression. Low water inlet temperature. Restriction in water line from
reservoir.
REFRIGERANT
Contaminated charge or bad compressor.
Low charge or gas leak.
Low suction pressure. Improper expansion valve sensing bulb. Location or insulation
and/or defective expansion valve
Check if extruding
head is down in
evaporator tube.
GEARMOTOR OVERLOAD
TRIPPED
Check water level control
and evaporator water tube
for lime build up restriction.
No
No
Yes
Refer to guide
CAUTION
CLEAN
to Good Ice in
Clear ice from
see
service manual.
evaporator and
instructions.
auger before re
setting over
load.
Reset
overload.
Icemaker runs
Reset but
Will not
motor does
reset.
not run.
Short run trips
Check
Overload
again in 2 min
gearmotor
hot try
utes. Check gear
circuit.
again.
motor circuit.
Will not
reset
replace
overload