iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Pipe inlets to pump are leaky or blocked
–
Check all supply lines to the pump for
leaks or blockages.
High pressure side is leaky
Pump leaky
–
Note
3 drops/minute are allowed.
With stronger leak, have device
checked by customer service.
High pressure pump is vibrating
Check all supply lines to the high-pres-
sure pump for leaks or blockages.
Appliance ventilation:
Unscrew the nozzle. Switch on the ap-
pliance and let it run until the water ex-
iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Warranty
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
In the event of a warranty claim please con-
tact your dealer or the nearest authorized
Customer Service centre. Please submit
the appliance, including all accessories,
and the proof of purchase.
24
General information
Accessories and Spare Parts
Warning
Risk of injury on account of unsuitable ac-
cessories. Only use accessories approved
for the working pressure of the appliance
(see "Specifications").
Only use accessories and spare parts
–
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
At the end of the operating instructions
–
you will find a selected list of spare parts
that are often required.
For additional information about spare
–
parts, please go to the Service section
at www.kaercher.com.
Guidelines for liquid rays
The accident prevention regulation (BGR
500) "Work with liquid rays" is valid. High
pressure spraying units must be checked
every 12 months in accordance with these
guidelines by an expert and the result of
this check must be written down.
– 10
EN