Important:
Observe the recommended fuse / breaker ratings provided in the product's documentation,
however be aware that the suitable fuse / breaker rating is dependent on the number of devices
being connected.
Implementation — direct connection to battery
• Where connection to a power distribution panel is not possible , the power cable supplied with
your product may be connected directly to the vessel's battery, via a suitably rated fuse or breaker.
• The power cable supplied with your product may NOT include a separate drain wire. If this is the
case, only the power cable's red and black wires need to be connected.
• If the power cable is NOT supplied with a fitted inline fuse, you MUST fit a suitably rated fuse or
breaker between the red wire and the battery's positive terminal.
• Refer to the inline fuse ratings provided in the product's documentation.
• If you need to extend the length of the power cable supplied with your product, ensure you
observe the dedicated Power cable extensions advice provided in the product's documentation.
1
Waterproof fuse holder containing a suitably-rated inline fuse must be fitted.
For suitable fuse rating, refer to: In-line fuse and thermal breaker ratings.
Product power cable.
2
3
Drain wire connection point.
Battery connection scenario A:
Suitable for a vessel with a common RF ground point. In this scenario, if your product's power cable is
supplied with a separate drain wire then it should be connected to the vessel's common ground point.
Battery connection scenario B:
Suitable for a vessel without a common grounding point. In this case, if your product's power cable is
supplied with a separate drain wire then it should be connected directly to the battery's negative
terminal.
Power cable extension
If you need to extend the length of the power cable supplied with your product, ensure you observe
the following advice:
• The power cable for each unit in your system should be run as a separate, single length of 2-wire
cable from the unit to the vessel's battery or distribution panel.