10. Syrup Tank Syrup System.
Disconnect syrup tank containing syrup from No. 1 syrup system.
Bag-in-Box Syrup System.
A.
Disconnect No. 1 syrup pump syrup inlet line from bag-in-box containing syrup.
B.
Cut connector from empty bag-in-box container, then connect connector to No. 1 syrup pump syrup
inlet line.
NOTE: Sanitizing solution is used in a more concentrated form because it will be diluted approximately
four-to-one in the product blender tank. If a powder type sanitizer is to be used, it must be thoroughly
dissolved with water prior to adding to a sanitizing solution container.
11. Using a clean syrup tank (syrup tank system) or a clean 5-gallon pail (bag-in-box system), prepare a full
tank or pail of sanitizing solution using Chlor-Tergent (Oakite Product, Inc.) or equivalent sanitizer. Mix san-
itizing solution by using 70 F to 100 F (max) plain water and 2.65 oz./gallon sanitizer. This mixture will
provide 800-ppm of chlorine. Sanitizing solution will be diluted to approximately 200-ppm inside the product
blender tank after carbonated water has been mixed with the sanitizing solution.
12. Syrup Tank System.
Shake sanitizing solution tank thoroughly to mix the solution, then connect tank to the No. 1 syrup system.
Bag-in-Box Syrup System.
Mix pail of sanitizing solution thoroughly, then immerse end of No. 1 syrup pump syrup inlet line into pail of
sanitizing solution.
13. Press SIDE 1 ''SYRUP PRIME'' switch to fill No. 1 syrup system syrup float switch with syrup.
14. Press SIDE 1 ''BLEND ON/OFF'' switch to fill No. 1 product blender tank with sanitizing solution. The car-
bonator water pump will start and begin pumping carbonated water into the product blender tank which will
dilute sanitizing solution also entering the tank.
15. After carbonator water pump cycles off, completely fill No. 1 freeze cylinder with sanitizing solution by re-
peatedly pulling and releasing the relief valve knob on the freeze cylinder faceplate and until sanitizing solu-
tion comes out of the relief valve port. Open the dispensing valve until sanitizing solution flows from the
valve, then close the valve. Open the product blender tank sample valve until sanitizing solution flows from
the valve, then close the valve.
16. Press SIDE 1 ''MOTOR'' switch to start No. 1 freeze cylinder beater. Allow sanitizing solution to remain in
the freeze cylinder for no less than 10 and no more than 15 minutes (max) contact time.
17. When sanitizing solution contact time has elapsed, press SIDE 1 ''OFF'' switch to stop the No. 1 freeze
cylinder beater.
18. Press SIDE 1 "BLEND ON/OFF" switch to prevent more sanitizing solution from entering the product
blender tank.
19. Place waste container under No. 1 dispensing valve nozzle. Open the dispensing valve and dispense all
sanitizing solution from the freeze cylinder. As sanitizing solution level lowers in the freeze cylinder, partially
close the valve to avoid spurting.
20. Place waste container under the No. 1 product blender tank product sample valve. Slowly open the valve
and purge remaining sanitizing solution out of the tank, then close the valve.
21. Syrup Tank System.
A.
Disconnect sanitizing solution tank from No. 1 syrup system.
B.
Connect syrup tank containing syrup into No. 1 syrup system.