Select Steering Type; Select Number Of Devices; Select Device Locations; Select Rpm Source - Dometic Optimus EPS Installation And User Manual

Electronic power steering with electric actuator
Table of Contents

Advertisement

EN
6.2.2

Select steering type

Select Outboard Optimus Electric from the list, as shown in figure 6-3.
Figure 6-3.
6.2.3

Select number of devices

The CANtrak will display a list of devices based on the system type. Use the +
and – buttons to change the quantity of each device to match the system.
These parameters tell the system how many of each device to look for on
the CAN network. If the numbers do not match you will get repeated error
messages from the display.
6.2.4

Select device locations

Each device on the network must be "instanced" correctly when there are
more than one of each type present. Instancing means teaching the system
which actuator is port, which is starboard, and which helm is main station,
and which is 2nd station.
The CANtrak will list all the devices on the CAN network along with their
serial numbers. Match the devices by the serial numbers and use the + and
– buttons to toggle between Port or Stbd, and Main or 2nd (or 3rd in
supported systems) station.
NOTICE!
Damage to the outboard engines may occur if the electric steering
actuators are not instanced correctly.
6.2.5

Select RPM source

The only valid RPM source is the default, CAN3, so you do not need to
change anything.
6-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ea1400Ea1000Ea1300