INSTALLATION

Install door external handle (if external handle is present)
Space Requirement
Keep enough space of door open.
Keep at least 50mm gap at two sides.
Leveling the unit
To do this adjust the two leveling feet at front of the unit.
If the unit is not level, the doors and magnetic seal alignments will
not be covered properly.
Note: Above pictures are for reference only.
Positioning
Install this appliance at a location where the ambient temperature
corresponds to the climate class indicated on the rating plate of the appliance:
Location
The appliance should be installed well away from sources of heat such as radiators, boilers,
direct sunlight etc. Ensure that air can circulate freely around the back of the cabinet. To ensure
best performance, if the appliance is positioned below an overhanging wall unit, the minimum
distance between the top of the cabi-net and the wall unit must be at least 100 mm. Ideally,
however, the appliance should not be positioned below overhanging wall units. Accurate leveling
is ensured by one or more adjust-able feet at the base of the cabinet.
Climate class
Ambient temperature
SN
+10 °C to +32 °C
N
+16 °C to +32 °C
ST
+16 °C to +38 °C
T
+16 °C to +43 °C
ENG - 40