Cornelius Flavorfusion TP01070 Training Manual page 22

Flavoroverload
Table of Contents

Advertisement

FlavorFusion® Training Manual
Power cord is
connected but
carbonator pump
does not run.
Carbonator pump is
short cycling with
every drink drawn
Carbonator tank
overfills, overflows
through relief valve,
and pump shuts off
after 5 minutes.
Publication Number: TP01070
Carbonator pump motor is disabled.
Probes were dry, unit was powered up,
water was not turned on, and
carbonator did not fill.
Water service was interrupted for more
than 5 minutes.
Lower liquid level probe reads "dry"
while upper probe reads "wet"
A. Poor electrical connections between
carbonator tank and main control board
B. Broken wires between carbonator
tank and main control board
C. Defective liquid level probes
Check the enable/disable switch on the
carbonator pump terminal box and
enable it, if necessary.
This results in a 5 minute timeout.
Unplugging the unit and plugging it in
will reset the unit and start the
carbonator pump.
Unplugging the unit and plugging it in
will reset the unit and start the
carbonator pump.
Check color of leads going to probes.
Black should go to bottom probe and
white to top probe. Reverse if incorrect.
A. Check connections at carbonator
tank and at connector J4 on the main
control board.
B. Replace wire harness
C. Replace both liquid level probes
- 18 -
© 2004-2007, IMI Cornelius Inc.