A.0 Appendix A.
Power Cables
+------------------------------------------------------------------------+
¦
¦ To avoid electrical shock, a power cable with a grounded ¦
¦
¦ attachment plug has been provided. Use only properly
¦ PICTURE 46
¦ grounded outlets.
¦
¦
¦
¦ Power cables used in the United States and Canada are
¦
¦ listed by Underwriter's Laboratories (UL) and certified
¦
¦ by the Canadian Standards Association (CSA). The power
¦
¦ cables consist of:
¦
¦
¦
¦
Electrical cables, type SVT or SJT.
¦
¦
¦
¦
Attachment plugs complying with National Electrical
¦
¦
Manufacturers Association (NEMA) 5-15P, that is:
¦
¦
¦
¦
"For 115 V operation use a UL Listed Cable Set
¦
¦
consisting of a minimum 18 AWG, Type SVT or SJT
¦
¦
three conductor cable a maximum of 15 feet in length ¦
¦
¦
and a parallel blade, grounding type attachment plug ¦
¦
¦
rated at 15 A, 125 V."
¦
¦
¦
¦
"For 230 V operation in the United States use a UL
¦
¦
Listed Cable Set consisting of a minimum 18 AWG,
¦
¦
Type SVT or SJT three conductor cable a maximum of
¦
¦
15 feet in length, and a tandem blade, grounding
¦
¦
type attachment plug rated at 15 A, 250 V."
¦
¦
¦
¦
Appliance couplers complying with International
¦
¦
Electrotechnical Commission (IEC) Standard 320,
¦
¦
Sheet C13.
¦
¦
¦
¦
¦
¦ Power cables used in other countries consist of:
¦
¦
¦
¦
Electrical cables, type HD21.
¦
¦
¦
¦
Attachment plugs approved by the appropriate testing ¦
¦
¦
organization for the specific countries where they
¦
¦
are used.
¦
¦
¦
¦
"For units set at 230 V (outside of U. S.): Use a
¦
¦
Cable Set consisting of a minimum 18 AWG cable and
¦
¦
grounding type attachment plug rated 15 A, 250 V.
¦
¦
The Cable Set should have the appropriate safety
¦
¦
approvals for the country in which the equipment is
¦
¦
to be installed and marked 'HAR'."
¦
¦
¦
¦ Figure 27 lists the power cable part number, the country ¦
¦
¦ where the power cable can be used, and an index number
¦
¦ to be matched with the receptacles shown in Figure 28.
¦
¦ If your power cable does not match this information,
¦
¦ contact your local dealer.
+------------------------------------------------------------------------+
+------------------------------------------------------------------------+
¦ Figure 27. Power Cable Information
+------------------------------------------------------------------------¦
¦ Part Number
¦ Country
+--------------------+-----------------------------------------+---------¦
¦ 1838574 Japan
¦ Bahamas, Barbados, Bolivia, Brazil,
¦
¦ Canada, Costa Rica, Dominican Republic, ¦
¦
¦ Ecuador, El Salvador, Guatemala,
¦
¦ Guyana, Haiti, Honduras, Jamaica,
¦
¦ Japan, Netherlands Antilles, Panama,
¦
¦ Peru, Philippines, Taiwan, Thailand,
¦
¦ Tobago, Trinidad, U.S.A. (except
¦
¦ Chicago), Venezuela
+--------------------+-----------------------------------------+---------¦
¦ 6952300 US/Canada
¦ Bahamas, Barbados, Bermuda, Bolivia,
¦
¦ Brazil, Canada, Cayman Islands,
¦
¦ Colombia, Costa Rica, Dominican
¦
¦ Republic, Ecuador, El Salvador,
¦
¦ Guatemala, Guyana, Haiti, Honduras,
¦
¦ Jamaica, Japan, Korea (South), Mexico,
¦
¦ Netherlands Antilles, Nicaragua,
¦
¦ Panama, Peru, Philippines, Puerto Rico, ¦
¦
¦ Saudi Arabia, Suriname, Taiwan,
¦
¦ Trinidad, U.S.A. (except Chicago),
¦
¦ Venezuela
+--------------------+-----------------------------------------+---------¦
¦ 6952301 6 ft
¦ Chicago, U.S.A.