Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the Fan Out value to fall from the
stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]
The following items appear only when you set Fan Control Mode to [Speed
Cruise Mode].
Target Speed [0]
Input value range: [0~4096]
Speed Tolerance [2]
Input value range: [0~64]
Fan Out Step Up Time [10]
Input value range: [0~255]
Fan Out Step Down Time [10]
Input value range: [0~255]
The following items appear only when you set Fan Control Mode to [Smart Fan
IV Mode].
Temperature Source [CPUTIN]
Allows you to select the temperature source. Configuration options: [SYSTIN]
[CPUTIN] [AUXTIN0] [AUXTIN1] [AUXTIN2] [AUXTIN3] [SMBUSMASTER
0] [SMBUSMASTER 1] [SMBUSMASTER 2] [SMBUSMASTER 3]
[SMBUSMASTER 4] [SMBUSMASTER 5] [SMBUSMASTER 6]
[SMBUSMASTER 7] [PECI Agent 0] [PECI Agent 1] [PCH_CHIP_CPU_
MAX_TEMP] [PCH_CHIP_TEMP] [PCH_CPU_TEMP] [PCH_MCH_TEMP]
[PCH_DIM0_TEMP] [PCH_DIM1_TEMP] [PCH_DIM2_TEMP] [PCH_DIM3_
TEMP] [BYTE_TEMP]