Electrical Connections - Hinkley 48" CHET Manual

Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL CONNECTIONS

REMEMBER - Turn off the power!
NOTE: Control must be installed within 30 feet of fan.
WARNING: Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire nuts, except for the
ground wire.
CAUTION: To reduce the risk of electric shock, this fan must be
installed with an isolating wall control/switch.
Insert the receiver into the ceiling mounting bracket with the flat
1
side of the receiver facing the ceiling. (Fig. 1)
Make wire connections from the fan to the receiver unit. For this
2
step use the bundle of 3 wires on the receiver. (Fig. 2)
Connect the BLUE fan wire to the BLUE receiver wire.
Connect the BLACK fan wire to the BLACK receiver wire.
Connect the WHITE fan neutral wire to the WHITE receiver
neutral wire.
3
Connect the wiring from the ceiling to the receiver unit. (Use the
2 wire bundle on the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply wire to the BLACK receiver
wire.
Connect the WHITE receiver neutral wire to the WHITE building
neutral wire.
Connect the COPPER building ground wire to the 2 GREEN
ground wires from the fan.
8
hinkley.com
Receiver
Figure 1
BLK(AC IN)
WH(AC IN)
Receiver
BLUE
WHITE
BLACK
BLACK
WHITE
BLUE
Figure 2
Hanger
bracket
GROUND
Outlet box
Ceiling

Advertisement