ELECTRICAL CONNECTIONS

REMEMBER -Turn off the power! NOTE - Control must be installed
within 30 feet of fan.
WARNINGS: Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire nuts, except for
the ground wire.
CAUTION: To reduce the risk of electric shock, this fan must be
installed with an isolating wall control/switch.
1. For best performance, make sure the Black Antenna and WIFI
Antenna, on the end of the receiver, remains extended and not
tangled with any of the electrical wires.
2. Make wire connections from the fan to the receiver unit. For this
step use the bundle of 5 wires on the receiver. (Fig. 1)
Connect the YELLOW fan wire to the YELLOW receiver wire.
Connect the GRAY fan wire to the GRAY receiver wire.
Connect the RED fan neutral wire to the RED receiver neutral
wire.
Connect the WHITE neutral light kit lead from the fan to WHITE
receiver lead marked " For Light".
Connect the BLACK light kit lead from the fan to BLUE receiver
lead marked "For Light".
Wire colors out of the fan are black/white for the light kit. Light
kit leads from the controller/receiver are blue/white.
3. Connect the wiring from the ceiling to the receiver unit. (Use the
2 wire bundle on the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply wire to the BLACK receiver
wire.
Connect the WHITE receiver neutral wire to the WHITE building
neutral wire.
Connect the COPPER building ground wire to the 4 YELLOW/
GREEN ground wires from the fan and receiver.
BLK (AC IN)
WH (AC IN)
BLUE (For light)
WHITE
(For light)
Receiver
GRAY
YELLOW
RED
RED
YELLOW
GRAY
BLACK
WHITE
Fig. 1
GROUND
Outlet box
Ceiling
Fan
07