Settings Via The Jumper Link; Settings Via Mppt Control Display; All Settings Explained - Victron energy BlueSolar MPPT 75/10 Manual

Mppt solar charger manual
Hide thumbs Also See for BlueSolar MPPT 75/10:
Table of Contents

Advertisement

5.1.2. Settings via the jumper link

If the load output algorithm is configured via VictronConnect or the MPPT Control display the jumper link is
not used and it needs to be removed. Configuration via the jumper link is only needed in case the load output
algorithm cannot be configured by any other means.
If the VE.Direct port is going to be used for communication with a GX device, MPPT display or other
equipment, the jumper needs to be removed, and cannot be used anymore for load output configuration. If this
is the case, configure the load output by using the VictronConnect App or a display. See chapter
settings [21]
or

Settings via MPPT Control display [15]

The load output algorithm can be configured via a jumper link, located in the VE.Direct connector:
• If VictronConnect or the MPPT Control display is used to configure the load output algorithm, the jumper link is not used.
Remove the jumper.
• If the jumper link is used, see the table below for the load output algorithm belonging to each jumper placement. Should the
VictronConnect App or display be used at a later stage to change the load output setting, the jumper link needs to be removed
beforehand.
Load output algorithm
BatteryLife algorithm
Alternatively, the load output algorithm has
been set via the VictronConnect App.
Conventional algorithm
low voltage disconnect: 11.1V
Automatic load reconnect voltage: 13.1V
Conventional algorithm:
low voltage disconnect: 11.8V
Automatic load reconnect voltage: 14.0V
The listed voltage values in this table are for 12V battery systems. For 24V and 48V battery systems multiply the listed 12V
values by respectively 2 and 4.
5.1.3. Settings via MPPT Control display
The optional
MPPT Control
display can be used to configure solar charger settings, with the exception of advanced settings such
as RX and TX port settings. For information on how to do this see the

5.2. All settings explained

This chapter lists all solar charger settings that are user-configurable and also explains how to update firmware of the solar
charger.
Do not change settings unless you know what they are and what the effect of changing these settings will
be. Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice
from an experienced Victron Energy installer, dealer or distributor.
Page 15
MPPT solar charger manual
for more information.
Jumper link
placement
port 75V models
No jumper link
Between pin 1 and 2
Between pin 2 and 3
MPPT Control
The MPPT Control
Load output
VE.Direct
VE.Direct port
100V models
manual.
Configuration and settings

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents