9 Servicing

The work described in this section is only to
be performed by personnel appropriately
qualified to carry out such tasks.
DANGER
!
Risk of fatal injury due to electric shock
(devices with 230 V supply voltage).
Î Before connecting wiring, performing
any work on the device or opening the
device, disconnect the supply voltage
and protect it against unintentional re-
connection.
Î Only use power interruption devices that
are protected against unintentional re-
connection of the power supply.
Note
The device was checked by SAMSON before
it left the factory.
− The product warranty becomes void if
service or repair work not described in
these instructions is performed without
prior agreement by SAMSON's After-sales
Service.
− Only use original spare parts by
SAMSON, which comply with the original
specifications.

9.1 Tuning zero and span

The ZERO and SPAN potentiometers are ac-
cessible on the front panel.
EB 6132 EN
SAMSON 6132
p/i Converter
Model 6132-
1
SAMSON 6132
Var.-ID
2
p/i Converter
Serial no.
3
Model 6132-
1
Input
4
Var.-ID
2
Serial no.
3
0
ZERO potentiometer
Input
4
0utput
Power supply
0
SPAN potentiometer
SAMSON AG D-60314 Frankfurt
SAMSON AG D-60314 Frankfurt
Î Disconnect the supply voltage and pro-
tect it against unintentional reconnection.
Î Remove any lines to upstream compo-
nents (pneumatic input signal) and any
wires to downstream control equipment
(electric output signal).
Î Connect the pneumatic input to a pres-
sure instrument and the electric output to
a measuring instrument with sufficient
accuracy.
Î Switch on supply voltage.
Î Tune zero:
Î Set the input signal to 0.2 bar.
The output signal of the measuring
instrument must now indicate
0/4 mA or 0/2 V.
Î Correct deviations at the ZERO
potentiometer.
Î Tune span:
Î Raise the input signal from 0.2 bar to
1 bar.
The output signal of the measuring
instrument must now indicate 20 mA
or 10 V.
Î Correct deviations at the SPAN po-
tentiometer.