Dimplex CDFI500P Owner's Manual page 9

Hide thumbs Also See for CDFI500P:

Advertisement

Installation
Figure 3
10 in.
(254 mm)
CDFI500P: 40 in
CDFI1000P: 80 in
Connecting Multiple Units Together
When connecting multiple units
together, the plumbing should be
constructed in a manifold style
configuration, sized appropriately
for the number of units that are be-
ing installed so a consistent volume
water and pressure is being sup-
plied to each unit.
New Construction
When determining a location for the
®
Opti-myst
cassette, ensure that the unit
will not be susceptible to drafts, vents,
ceiling fans and other air currents.
Similar to a candle, large movements of
air will affect the unit's ability to create
and maintain the flame effect.
If the desired location is susceptible
to significant air movement, i.e. air
vents, the different installation options
illustrated in Figure 3 can be used. It is
10 in.
(254 mm)
3 in.
(77 mm)
3 in.
(77 mm)
Air Inlet
2
(258 cm
2
(516 cm
3 in.
(77 mm)
3 in.
(77 mm)
)
2
)
2
important that the surface surrounding
the top of the cassette have at least a
3" (72 mm) clearance from any vertical
surface and the barrier be 10" (254 mm)
high from the installation surface, to
ensure optimal flame production.
!
NOTE: It is recommended that
during drywall installation and fin-
ishing the media plate be installed
with the provided bag to prevent
dust and debris from entering the
unit.
Use studs to frame an enclos-
1.
ure with the following minimum
internal/opening dimensions -
see Figure 2.
NOTE: A fresh air inlet that is a
!
minimum of 80 in
CDFI1000P and 40 in
for the CDFI500P, is required for
optimum mist production (Figure 2
10 in.
(254 mm)
3 in.
(77 mm)
) for the
2
2
(516 cm
2
(258 cm
)
2
9