Siemens SIMATIC RF1100 Operating Instructions Manual page 34

Hide thumbs Also See for SIMATIC RF1100:
Table of Contents

Advertisement

Configuring with the WBM
7.1 Starting WBM
Procedure
Proceed as follows to start the WBM:
1. Start your Web browser.
2. Enter the IP address of the reader preceded by "https://" in the address field of your browser.
3. Confirm your entry by pressing the <Enter> key.
Note
Updating HTTPS certificates
The first time you log on, the HTTPS certificate of the reader is shown as not secure. Note that
the certificate stored in the reader is only intended to ensure that the initial connection
establishment to the reader is encrypted. Confirm that the certificate is secure. Then transfer
your own, secure certificate to the reader.
Result: The WBM of the reader opens.
Note
The connection to the reader cannot be established
If no connection can be established to the reader, check the following points:
• Make sure that all cables are correctly connected.
• Make sure that the reader has started up.
• Check the IP addresses of the PC and the reader, as well as the subnet mask. Both IP addresses
must be located in the same subnet.
• Make sure that the connection is not blocked by a firewall.
• Check the connection between the PC and reader using a ping request.
Logging into the WBM for the first time
When logging into WBM for the first time, a popup window appears prompting you to log in with
the default user "admin".
1. Select the required interface language from the drop-down list.
2. Enter the preset default user name "admin" in the "User" text box.
3. Enter the preset default password "admin" in the "Password" text box.