can find detailed information on the Syslog messages, their structure and contents in the
section "Syslog messages".
With the "Update" button, you can read in the entries from the reader again and update the
list. The displayed log entries contain 128 KB of data.
7.3.8

The "Edit transponder" menu item

You can read out and write transponder data with the "Edit transponder" menu item.
This page is divided into the following areas:
• Read UID
• Read/write
Figure 7-10
The "Edit transponder" menu item
Read UID
You can read out the UID (Unique Identifier) of the transponder in the "Read UID" area.
Read/write
In the "Read/write" area, you can read out and overwrite the memory areas. You can access
pre-defined addresses (tag fields). Using the parameters, you can adapt the memory area
manually.
Table 7-11
Parameter
Tag fields
VHL ID
Start address
SIMATIC RF1100
Operating Instructions, 08/2023, C79000-G8976-C698-02
Description of the parameters of the tag fields
Description
List with predefined addresses.
ID of the configuration stored in the reader.
Input box for entering the address within the selected
tag field from which you want to read, change or
write the data of the target transponder. You can use the button to change
the input/output format (decimal or hexadecimal).
Range of values: 0 ... 65535
Configuring with the WBM
7.3 The menu items of the WBM
53