Managing System
User authentication mode: IP based
Index IP Address
-----
-----------------
1
192.168.0.0/24
Switch(config)#end
Switch#copy running-config startup-config

5.2.2 Configuring the HTTP Function

Follow these steps to configure the HTTP function:
Step 1
configure
Enter global configuration mode.
Step 2
ip http server
Enable the HTTP function. By default, it is enabled.
Step 3
ip http session timeout minutes
Specify the Session Timeout time. The system will log out automatically if users do nothing
within the Session Timeout time.
minutes
Step 4
ip http max-users admin-num guest-num
Specify the maximum number of users that are allowed to connect to the HTTP server. The
total number of users should be no more than 16.
For T1600G-18TS, the number of Operator, Power User and User can be set respectively.
admin-num
are from 1 to 16.
guest-num
or User. The valid values are from 0 to 15.
Step 5
show ip http configuration
Verify the configuration information of the HTTP server, including status, session timeout,
access-control, max-user number and the idle-timeout, etc.
Step 6
end
Return to privileged EXEC mode.
Step 7
copy running-config startup-config
Save the settings in the configuration file.
The following example shows how to set the session timeout as 9, set the maximum admin
number as 6, and set the maximum guest number as 5.
Switch#configure
Access Interface
-------------------------------
SNMP Telnet HTTP HTTPS
: Specify the timeout time, which ranges from 5 to 30 minutes. The default value is 10.
: Enter the maximum number of users whose access level is Admin. The valid values
: Enter the maximum number of users whose access level is Operator, Power User
Access Security Configurations
Configuration Guide