Monitored Entrapment Protection Installation

! IMPORTANT:
A minimum of one Monitored External Entrapment Sensor is required to be
connected to the UL terminal OR the Re-Open terminal. If there is a possible entrapment
zone in the open direction, an external sensor MUST be wired to the "UL" input or the
installation will not comply with UL 325.
"UL"
Protects against entrapment in both the opening and closing directions. Input will
reverse the gate momentarily in the opposite direction it was traveling. Refer to page 22.
"Re-Open"
Protects against entrapment in the closing direction ONLY. Input will reverse the
gate all the way to the Open Limit. Refer to page 22.
STEP 1:
Connect the monitored entrapment
protection sensor(s) to the Viking Control
Board.
UL LEARN
NO LEARN
10K Monitored Terminal
10K Monitored Terminal

Manual Release

When manual operation is required:
a. Open the cover to the Lock
b. Inset the Release Key into the Lock
and rotate towards the gate post.
c. Pull the Lever out and manually
move the gate.
VIKING TECHNICAL SUPPORT 1.800.908.0884
IMPORTANT SAFETY INFORMATION
Refer to page 22 for detail
STEP 2:
Execute the Learn Process:
• Press and release the "Diagnose" button
until you see
LCD Display.
• Press and hold the "Stop" button.
• Toggle the "Diagnose" button once.
• The number of Monitored sensors
connected to the "UL" or "Re-Open"
terminals will now be displayed.
EXAMPLE:
UL LEARN
UL2
UL SENSOR ERRORS:
If a problem occurs with one of the monitored
entrapment sensors, the "Stop" LED will illuminate
and an ERR message will be displayed, indicating
which input terminal(s) the sensor is connected to.
TERMINAL:
"UL"
ERR SENS
ERROR
MESSAGE:
UL
b
c
UL LEARN NO LEARN
RO1
"Re-Open"
"UL" & "Re-Open"
ERR SENS
ERR SENS
RO
UL
Manual Release
To reengage the gate:
Close the Lever back and
rotate the Release Key away
from the gate post.
Manually move the gate
towards the Manual Release
Assembly until engaged.
on the
RO
7