[ Table 2-3 : Maximum Charge Current Limit ]; [ Figure 2-1 : Derating Curve ]; [ Figure 2-2 : Battery Charge Limit ] - Q CELLS Q.HOME+ ESS HYB-G2 User Manual

Hide thumbs Also See for Q.HOME+ ESS HYB-G2:
Table of Contents

Advertisement

5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Item
Maximum
Charge Current(*)
(*) : Maximum Charge Current
- If the battery is discharged at the maximum discharge current / power, the battery should
be cooled its ambient temperature before discharging again.
09
I
Safety
20
30
Ambient temperature (°C)

[ Figure 2-1 : Derating Curve ]

Cell body / module temperature
Q.SAVE
G2
4kWh
Cell body temperature
T < -10 °C
-10 °C ≤ T < 0 °C
Q.SAVE
G2
0 °C ≤ T < 10 °C
6.3kWh
10 °C ≤ T < 20 °C
20 °C ≤ T < 45 °C
45 °C ≤ T < 55 °C
55 °C ≤ T

[ Table 2-3 : Maximum Charge Current Limit ]

40
50
T < 0 °C
0 °C ≤ T < 10 °C
10 °C ≤ T < 25 °C
25 °C ≤ T < 40 °C
40 °C ≤ T < 50 °C
50 °C ≤ T
Max Cell V
-
Max Cell V < 3.8
3.8 ≤ Max Cell V < 3.9
3.9 ≤ Max Cell V
Max Cell V < 3.8
3.8 ≤ Max Cell V < 4.0
4.0 ≤ Max Cell V
Max Cell V < 3.8
3.8 ≤ Max Cell V
-
-
-
Australia & New Zealand
Germany
60
70
Specification
0 A
3.5 A
7 A
9.8 A
3.5 A
2.1 A
Specification
0 A
7.5 A
3 A
0 A
7.5 A
3 A
0 A
15.6 A
10 A
15.6 A
10 A
3 A

Advertisement

Table of Contents
loading

Table of Contents