Summary of Contents for Regency Fireplace Products U32
Page 1
Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 919-432 REGENCY FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 12.18.14...
Page 2
The Regency Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The models U32-NG10 and U32-LP10 of this series have been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
Page 3
Regency Mobile/Manufactured Home Listed appliance equipped with a dedicated #8 ground lug to which an 18 gauge comes factory equipped with a means to secure the unit. copper wire from the steel chassis ground must be attached. U32-10 Regency Direct Vent Gas Insert ®...
General Vent Maintenance ..........24 Log Replacement ............24 Glass Gasket ...............24 Door Glass ..............24 Fan Maintenance ............25 Valve Replacement ............26 Main Assembly ............27 Burner Assembly & Log Set.........28 Low profile faceplate ...........29 Warranty ..............31 U32-10 Regency Direct Vent Gas Insert ®...
Page 5
This is a copy of the labels that accompany each U32-10 Gas Insert. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is We have printed a copy of the contents here for your review.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. U32-10 Regency Direct Vent Gas Insert ®...
IN THE SAME AREA AS THE APPLI- INSTRUCTIONS ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE The U32 Gas Insert must be installed in accordance TO ACCIDENTAL CONTACT BURNS. A with these instructions. Carefully read all the PHYSICAL BARRIERS IS RECOMMEND- instructions in this manual first.
FOR YOUR SAFETY 4) See general construction and assembly instructions. This appliance may only be The U32-10 Gas Inserts have been tested and installed in a vented, noncombustible approved to be vented into any masonry fireplace This appliance requires air for proper combustion.
Secure with gear recommend using the Simpson Dura-Vent clamp. System (46dva-GK adapter and 46dva-VCH high-wind cap). The Air Intake pipe must be attached to the inlet Inlet air collar of the termination cap. 10 | U32-10 Regency Direct Vent Gas Insert ®...
Regency Note: To properly check gas pressure, both Installer at the time of installation or inlet and manifold pressures should service. be checked using the valve pressure Diagram 2 ports on the valve. U32-10 Regency Direct Vent Gas Insert ®...
4) Fit log 27-32 into the pins on the middle left hand side of the burner. 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. 27-32 12 | U32-10 Regency Direct Vent Gas Insert ® 12/13/07 918-679a...
Page 13
7) Fit the bottom end of log 27-35 into the pin in log 27-33 and rest the top end of log 27-35 on the notch in log 27-31. 27-33 27-35 27-33 U32-10 Regency Direct Vent Gas Insert ® 918-679a 12/13/07...
Page 14
8) Fit log 27-36 into the pins on logs 27-33 and 27-31. 10) Separate platinum embers and place on the burner just in front of the logs as shown. Avoid stacking platinum embers. 27-31 27-36 27-33 Platinum Embers 27-36 14 | U32-10 Regency Direct Vent Gas Insert ® 12/13/07 918-679a...
Attach to the floor of the unit with a velcro pad. 2) See Remote Control installation instructions for information on coding the handheld transmitter to the receiver. 918-679a U32-10 Regency Direct Vent Gas Insert 12/13/07 ®...
INSTALLATION Install the supplied battery into the DC Sparker Box by opening the battery compartment. Diagram 3 NOTE: The battery in the DC Sparker Box will need to be replaced annually. 16 | U32-10 Regency Direct Vent Gas Insert ®...
CONVERSION KIT # 426-969 FROM NG TO LP Conversion from NG to LP for using SIT 829 NOVA Gas Valve U32-10 using SIT 829 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! IMPORTANT 10. Remove NG stepper motor by removing...
Connect the male end black and red fan switch wires (in the NOTE: Diagram shown without faceplate backing installed to better illustrate location of holes. black casing) to the wire connectors from the fan speed control. Diagram 4 Diagram 7 18 | U32-10 Regency Direct Vent Gas Insert ® 09.30.14 919-460...
Page 19
Attach the bottom louver to the 2 hinges using 3 screws per hinge. Outer faceplate Back faceplate Slot brackets Diagram 11 Diagram 9 10. Hook screen door over glass frame. Final Install Diagram 12 Diagram 10 11.05.14 919-460 U32-10 Regency Direct Vent Gas Insert ®...
2. Proceed to faceplate installation–see faceplate instructions in manual or with faceplate. Assembled Faceplate Backer + spacer Backing Plate (backside) (backside) 3. Proceed to faceplate installation–see faceplate instructions in manual or with faceplate. 20 | U32-10 Regency Direct Vent Gas Insert ®...
250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or NOTE: When the wall thermostat is connected, the remote control transmitter UL approved may be used. and all of its features are now disabled. U32-10 Regency Direct Vent Gas Insert ®...
"OFF". 2. Turn the gas control knob to the "OFF" position to turn off the pilot. Pilot may be shut off during prolonged non use periods to conserve fuel. 22 | U32-10 Regency Direct Vent Gas Insert ®...
5) Keep the area near the appliance clear and in volume depending on the speed setting of your free from combustible materials, gasoline and Proflame other flammable vapours and liquids. fan speed control. video U32-10 Regency Direct Vent Gas Insert ®...
1 flowing across the rear of the burner (it does not have to be touching the burner). If you have an incorrect flame pattern, contact your Regency dealer for further instructions. GENERAL VENT 24 | U32-10 Regency Direct Vent Gas Insert ®...
Hood to the rear firebox wall and lift out. 8) Remove the 10 screws holding the Access Panel in place. 9) Remove the Fan Air Duct by loosening the 3 screws, squeeze the sides together to remove. U32-10 Regency Direct Vent Gas Insert ®...
16) Fire up the unit again and check for proper 4) Reconnect the quick drop out thermocouple flame appearance and glow on logs. nut with a 9mm wrench. 5) Reconnect the pilot tube nut with a 7/16" 26 | U32-10 Regency Direct Vent Gas Insert ®...
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Excalibur Product.
Page 32
Register your Regency warranty online ® www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.
Need help?
Do you have a question about the U32 and is the answer not in the manual?
Questions and answers