08 27224 00 - Prima 60G
Data badge
Lower part of front frame and rear of
appliance.
Pressure setting
Cat I
(GB/IE)
2H
Gas category
I
2H
Appliance class
Class 3
Ignition
Mains operated re-ignition generator
Oven light
25W
Electrical supply
220 - 240V ~ 50Hz, 44W
26/1/05
9:22 am
Page 27
Technical Data
Grill
Nominal Rate Qn
Injector
Spark gap
G20 @ 20mbar
Oven
Bray type burner, sheet steel body,
stainless steel flame strip
Nominal Rate Qn
Injector
Spark gap
Thermostat bypass
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re) fitting.
Maximum heat input
Qn 2.5kW
Countries of destination
GB - Great Britain, IE - Ireland
25
2.4kW
1.12mm
3 - 4mm
2.5kW
1.25mm
3 - 4mm
50