Maintenance And Troubleshooting - ICON PFEL03815.7 User Manual

Table of Contents

Advertisement

MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the hybrid trainer is used.
Replace any worn parts immediately.
To clean the hybrid trainer, use a damp cloth and a
small amount of mild soap. IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
The console requires activation. If you have not
activated the console, see assembly step 19 on
page 16.
Most console problems are the result of low batteries.
To replace the batteries, see assembly step 13 on
page 13.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 21.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the
reed switch, first
remove the two
M4 x 19mm Self-
tapping Screws
(100) from the
Rear Access Cover
(26), and then
remove the Rear
Access Cover.
26
100
Next, locate the Reed Switch (60). Slightly loosen the
two M4 x 19mm Screws (84).
117
48
Next, rotate the Large Pulley (48) until a Pulley Magnet
(117) is aligned with the Reed Switch (60). Slide the
Reed Switch slightly toward or away from the Pulley
Magnet. Then, retighten the M4 x 19mm Screws (84).
Rotate the Large Pulley (48) for a moment. Repeat
these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the rear access cover.
25
60
84

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro-form hybrid trainer

Table of Contents