11 Removal
The work described in this section is only to
be performed by personnel appropriately
qualified to carry out such tasks.
Before removing the valve, make sure the fol-
lowing conditions are met:
− The actuator is put out of operation (see
the 'Decommissioning' section).
11.1 Removing the actuator
from the valve
See Fig. 11-1
1. Remove external piping.
2. Remove the clamps of the stem connec-
tor.
3. Unscrew the stem connector nut and lock
nut from the valve.
4. Unscrew the ring nut on the valve bon-
net.
5. Separate the actuator from the valve by
undoing the ring nut.
6. Fasten the lock nut and stem connector
nut on the valve.
EB 8314-1 EN
Removal
11-1